Some contamination does not stay in the ground. Chemical vapors can move up through the soil and into a building. This is vapor intrusion. It can affect the people in the building, the value of the property, and the loan. This guide explains how it works and how Washington evaluates it.
This guide is general information. It is not legal, health, or lending advice.
The short version
- Vapor intrusion starts with volatile chemicals in soil or groundwater.
- Dry cleaners, gas stations, and sites that used solvents are common sources.
- A Phase I ESA can identify the concern. It does not test for it.
- Washington’s Department of Ecology has a tiered guidance document for the tests.
- TCE needs fast action.
- Mitigation systems can protect a building while the source is cleaned up.
What vapor intrusion is
Ecology’s guidance explains it this way. When volatile hazardous substances such as gasoline or solvents are released, they can contaminate soil and groundwater. The contamination can form chemical vapors. The process by which these vapors migrate through the soil and into indoor air is called vapor intrusion.
The vapors enter a building through openings. Ecology lists cracks, seams, and utility penetrations in subsurface walls and floors. Sewer lines and other utility corridors can also carry vapors.
The health concern
EPA says the main concern in most buildings is long-term exposure to low levels of these chemicals. In extreme cases, vapors can build up to levels that pose near-term safety hazards or acute health effects. Ecology says those cases are relatively rare.
Which sites cause it
EPA names petroleum hydrocarbons and chlorinated solvents as chemicals that can threaten indoor air through this pathway. Its examples include trichloroethylene and benzene. These chemicals connect to common commercial property types.
| Site type | Typical volatile chemicals | Why it matters |
|---|---|---|
| Dry cleaners | Chlorinated solvents such as tetrachloroethene (PCE) and trichloroethene (TCE), and petroleum-based solvents | Solvents can enter soil, soil vapor, and groundwater |
| Gas stations | Petroleum hydrocarbons from gasoline | Ecology has a separate screening process for petroleum sites |
| Industrial sites that used solvents | Chlorinated solvents such as TCE | TCE has a short-term health concern |
The source does not have to be on your property. Vapors can come from contamination that moved under your building from a nearby site. A past use matters as much as a current use.
See our pages on dry cleaners and laundromats, gas stations, and industrial and manufacturing sites.
How a Phase I ESA treats vapor migration
ASTM E1527-21 is the Phase I standard that EPA recognizes for all appropriate inquiries. The goal of a Phase I is to identify recognized environmental conditions (RECs). A REC is based on a release, a likely release, or a material threat of a future release.
Vapor is part of that picture. EPA addressed it in 2013, when it recognized the earlier E1527-13 version. EPA noted that ASTM revised the definition of “migrate” to specifically include vapor migration. EPA also wrote that “vapor migration has always been a relevant potential source of release” that may warrant identification.
In practice, this means two things:
- The environmental professional should consider if vapors from a release could reach the property.
- A Phase I is a records and site review. It does not include soil gas or indoor air samples.
If the Phase I identifies a vapor concern, the next step is testing. Read Phase I vs Phase II ESA for the difference. Our Phase II checker can help you sort your Phase I findings.
Ecology’s guidance: publication 09-09-047
Ecology’s document is the Guidance for Evaluating Vapor Intrusion in Washington State: Investigation and Remedial Action. The publication number is 09-09-047. Ecology published the final version in March 2022.
The guidance was developed under Washington’s cleanup law, the Model Toxics Control Act (MTCA). Ecology says it expects all site investigations to assess the vapor intrusion pathway when volatile hazardous substances are present in the subsurface.
The tiered approach
| Stage | Where the work is done | What it answers |
|---|---|---|
| Preliminary Assessment | Desk review of site data | Are the chemicals volatile and toxic, and are buildings close enough? |
| Tier 1 evaluation | Outside the building | Are soil gas or groundwater levels high enough to affect indoor air? |
| Tier 2 evaluation | Inside the building | Are indoor air levels from vapor intrusion unacceptable? |
Preliminary Assessment
The first questions are simple. Are the chemicals volatile and toxic enough? Are buildings close to the contamination?
Section 2.3 of the guidance gives distances. Buildings more than 30 feet horizontally from the edge of volatile petroleum contamination are unlikely to have unacceptable impacts. For other volatile contamination, the distance is 100 feet.
Ecology warns against the use of distance alone. Sewer lines, utility corridors, and very permeable ground can carry vapors farther.
Tier 1: screening
A Tier 1 evaluation uses data from outside the building. The consultant collects soil gas or groundwater samples. The results are compared to generic screening levels in Ecology’s Cleanup Levels and Risk Calculation (CLARC) data tables.
A Tier 1 evaluation can also be done for a building that is not built yet. This helps a buyer that plans new construction.
Tier 2: sub-slab and indoor air sampling
A Tier 2 evaluation moves inside. The guidance says it typically includes indoor air samples, plus ambient air and sub-slab soil gas or crawl space air.
The other samples have a purpose. Indoor air can contain the same chemicals from cleaners, paints, or stored gasoline. Sub-slab and ambient air results help show what part comes from the ground.
If indoor air from vapor intrusion exceeds the cleanup levels, the guidance says to quickly implement mitigation or other measures to protect the people inside.
The short-term concern for TCE
Most vapor intrusion concerns are about long-term exposure. TCE is different. Appendix A of the guidance says that in 2014, EPA concluded that short-term inhalation exposures to TCE in indoor air have the potential to cause serious heart defects in a developing fetus. The damage can occur early in a pregnancy.
For this reason, Ecology sets short-term action levels. Table A-2 of the guidance is titled “Vapor intrusion TCE Indoor Air Action Levels, short-term (maximum 3-week mean concentration for women of childbearing age).” It gives these values:
| Level of concern in Table A-2 | Concentration | Basis in Table A-2 |
|---|---|---|
| Unrestricted (residential) land use | 2.0 µg/m3 | 24 hours per day, 7 days per week |
| Workplace scenario (commercial or industrial) | 7.5 µg/m3 | 45-hour work week |
Ecology notes that these action levels are not cleanup levels. The long-term cleanup levels for TCE are lower, and they are in the CLARC tables.
The guidance asks for speed. It says protective actions should occur as rapidly as possible after discovery, usually within days or weeks. It also calls for prompt contact with the people who live and work near the contamination.
For a buyer or lender, the point is direct. If TCE is a possible contaminant near an occupied building, do not let the question wait.
Common mitigation types
Mitigation protects the people in the building. It does not usually clean up the source. Section 6.2 of the guidance describes these general types:
- Sub-slab depressurization. A fan or blower makes the pressure under the slab lower than the pressure inside. This stops soil gas from flowing in. Ecology says active systems are proven to reduce vapor levels for a range of building types.
- Physical barriers. These include sealed openings in floors and walls. A membrane under a new building is another type. Ecology says a membrane should be combined with a venting system.
- Building pressure and ventilation. Some HVAC systems can keep a positive pressure indoors. More ventilation can also dilute the vapors. Ecology notes that these methods often use more energy.
- Indoor air treatment. These devices typically use carbon to remove the chemicals from the air.
For long-term protection, Section 7.3 gives two options. The cleanup can lower the levels in the ground until vapor intrusion is unlikely. Or the site can use institutional controls and, if needed, engineered controls.
What this means for a deal
- Buyers. Ask about past dry cleaners, fuel sales, and solvent use on the property and next to it. Plan time for testing if the Phase I raises a vapor concern.
- Lenders. A vapor concern can lead to a Phase II and to mitigation costs. For SBA loans on dry cleaner properties, the SBA procedure requires the investigation to address soil vapor. See SBA loan environmental requirements.
- Owners. A mitigation system needs operation and checks over time. Keep the records. A later buyer will ask for them.
When the source needs cleanup, read our guide to the Voluntary Cleanup Program and No Further Action in Washington.
Next step
If a Phase I points to a vapor concern, get it tested before you close. See our vapor intrusion assessment service and our Phase II Environmental Site Assessment service. You can also contact Kee Enviro to talk through your property.