Skip to content
Closing soon? See the latest date to order each report.Free timeline →
Get a quote

Industrial Property Due Diligence in Puget Sound

Find what the plant left behind.

Short answer

Industrial and manufacturing properties often have more than one source of contamination: degreasing solvents such as TCE, metals from plating and machining, PCBs from old electrical equipment, and petroleum from tanks. A Phase I finds the likely sources. A Phase II tests soil, groundwater, and soil vapor near them. TCE vapor is a special concern because Ecology sets short-term indoor air action levels for it.

Round cast iron cover stamped Monitoring Well, set flush in concrete.

What we often find at industrial and manufacturing

01

Chlorinated solvents (TCE and PCE)

Vapor degreasers and parts cleaners used TCE and PCE. These solvents are heavier than water, so they can sink through soil and groundwater. They can also move as vapor into buildings.

02

Metals

Plating, machining, welding, and metal finishing can leave chromium, nickel, lead, and other metals in soil, sumps, and floor drains.

03

PCBs

Older transformers, capacitors, and hydraulic systems can contain PCBs. Leaks stain concrete and soil.

04

Petroleum

Fuel and heating tanks, forklifts, and oil storage areas add petroleum to the list.

05

Sumps, trenches, and floor drains

Process drains and sumps collect spills. Cracks let liquids into the soil below the slab.

06

Stormwater and loading areas

Outdoor storage and loading docks can release oil and metals to stormwater systems and soil.

Interactive site explorer

Look below a metal finishing plant

One building can hold solvents, metals, and PCBs. Tap a marker to see each source and how we test it.

GROUNDWATER FLOW356124

Tap a number to inspect

Labeled soil and groundwater sample jars ready for the lab

Many industrial and manufacturing properties sit in the Kent Valley, Tukwila, Georgetown, Fife, and the Tacoma tideflats. They can have complex histories. One building can have had five tenants and three different industries over 50 years. Kee Enviro helps buyers, lenders, and owners find out what that history left in the ground.

Who this page is for

  • Buyers and developers. You want to buy, convert, or redevelop an industrial building. You need the risk and the likely cost before you close.
  • Lenders. You need a report you can rely on for a loan on an industrial property.
  • Owners and landlords. You want to sell, refinance, or document conditions between tenants.

Common sources on industrial sites

Source What it can release How we test
Vapor degreasers and parts cleaners TCE, PCE, and their breakdown products Soil, groundwater, sub-slab vapor, and indoor air samples
Plating and metal finishing lines Chromium, nickel, cadmium, cyanide Soil and sump sediment samples, groundwater if needed
Machining and welding Cutting oils, metals Soil samples near work areas and drains
Transformers and old hydraulic equipment PCBs Wipe samples on concrete, soil samples
Fuel and oil tanks Gasoline, diesel, heavy oil Soil and groundwater samples near the tank and piping
Sumps, trenches, and floor drains Any liquid used in the building Sediment samples and soil borings below the drain

Why vapor matters

Chlorinated solvents move as vapor through soil and into buildings through cracks and utility openings. This is called vapor intrusion. Ecology’s vapor intrusion guidance (publication 09-09-047, revised March 2022) sets how to test and when to act. Its Appendix A includes short-term action levels for TCE in indoor air. If a building is occupied, a TCE result above those levels can need a fast response.

We test vapor in stages. We start with sub-slab vapor points. If results are high, we add indoor air samples and look at the building’s ventilation. See our vapor intrusion assessment page for the steps.

Reporting a release

Washington’s cleanup rule requires an owner or operator to report a release to Ecology within 90 days of discovery. Some releases have shorter deadlines. Ask us or your attorney before you collect data that you may need to report.

Buying, selling, or refinancing

  1. Order a Phase I. We review tenant history, permits, aerial photos, and agency files, and walk the whole building.
  2. Order a Phase II if needed. We target the sources the Phase I found. We send a written scope and price first.
  3. Plan cleanup or controls. Some sites need excavation. Others need a vapor mitigation system or a cleanup through Ecology’s Voluntary Cleanup Program.

Next step

Start with a Phase I Environmental Site Assessment. If you already know about solvents or a plating line, see our Phase II services. Call Kee Enviro at 206-914-4989.

Services for industrial and manufacturing

Industrial and Manufacturing: FAQ

Why does TCE get special attention?

TCE can harm a developing fetus after short exposures. Ecology's vapor intrusion guidance includes short-term TCE action levels for indoor air, so a positive result can need fast action at an occupied building.

The property was a warehouse. Do I still need a Phase II?

Not always. The Phase I decides. Many warehouses had light manufacturing, forklift charging, or tenant operations at some time. Old aerial photos, city directories, and permits show the history.

Can you test under the slab without stopping operations?

Usually, yes. We drill small borings and install sub-slab vapor points with portable equipment. We schedule work around shifts and keep the work area small.

Who is liable for contamination from a past tenant?

Under Washington's Model Toxics Control Act, liability is strict, joint and several. Current owners and past owners and operators can be liable. Ask an attorney about cost recovery and the protections a Phase I can support.

Can an industrial site get a No Further Action opinion?

Yes. Many owners clean up through Ecology's Voluntary Cleanup Program and request a written opinion. Some larger sites go through formal cleanup with Ecology instead.

Guides

Contaminated Soil Removal Cost in Washington: What Drives the Price →Environmental Covenants in Washington: What Buyers Should Know →MTCA Cleanup Levels Explained: Method A, B, and C →My Phase I Found a REC. What Happens Next? →Phase I vs Phase II ESA: What Is the Difference? →Vapor Intrusion in Washington: What Buyers and Lenders Should Know →Washington Voluntary Cleanup Program: How to Get a No Further Action Opinion →

Sources: Washington State Department of Ecology, Guidance for Evaluating Vapor Intrusion in Washington State, publication 09-09-047 · ATSDR, ToxFAQs: Trichloroethylene (TCE) · U.S. EPA CLU-IN, Dense nonaqueous phase liquids (DNAPLs) overview · 40 CFR 433.13, Metal finishing pretreatment standards · U.S. EPA, Learn about polychlorinated biphenyls (PCBs) · WAC 173-340-900, Table 830-1, Required testing for petroleum releases · Washington State Legislature, RCW 70A.305.040, Liability · Washington State Department of Ecology, Contaminated property considerations, publication 22-09-021 · Washington State Department of Ecology, Voluntary Cleanup Program: Before you apply · WAC 173-340-300, Site discovery and release reporting · WAC 173-360A-0750, Reporting and cleanup of confirmed releases from UST systems

Tell us about your property.