Many industrial and manufacturing properties sit in the Kent Valley, Tukwila, Georgetown, Fife, and the Tacoma tideflats. They can have complex histories. One building can have had five tenants and three different industries over 50 years. Kee Enviro helps buyers, lenders, and owners find out what that history left in the ground.
Who this page is for
- Buyers and developers. You want to buy, convert, or redevelop an industrial building. You need the risk and the likely cost before you close.
- Lenders. You need a report you can rely on for a loan on an industrial property.
- Owners and landlords. You want to sell, refinance, or document conditions between tenants.
Common sources on industrial sites
| Source | What it can release | How we test |
|---|---|---|
| Vapor degreasers and parts cleaners | TCE, PCE, and their breakdown products | Soil, groundwater, sub-slab vapor, and indoor air samples |
| Plating and metal finishing lines | Chromium, nickel, cadmium, cyanide | Soil and sump sediment samples, groundwater if needed |
| Machining and welding | Cutting oils, metals | Soil samples near work areas and drains |
| Transformers and old hydraulic equipment | PCBs | Wipe samples on concrete, soil samples |
| Fuel and oil tanks | Gasoline, diesel, heavy oil | Soil and groundwater samples near the tank and piping |
| Sumps, trenches, and floor drains | Any liquid used in the building | Sediment samples and soil borings below the drain |
Why vapor matters
Chlorinated solvents move as vapor through soil and into buildings through cracks and utility openings. This is called vapor intrusion. Ecology’s vapor intrusion guidance (publication 09-09-047, revised March 2022) sets how to test and when to act. Its Appendix A includes short-term action levels for TCE in indoor air. If a building is occupied, a TCE result above those levels can need a fast response.
We test vapor in stages. We start with sub-slab vapor points. If results are high, we add indoor air samples and look at the building’s ventilation. See our vapor intrusion assessment page for the steps.
Reporting a release
Washington’s cleanup rule requires an owner or operator to report a release to Ecology within 90 days of discovery. Some releases have shorter deadlines. Ask us or your attorney before you collect data that you may need to report.
Buying, selling, or refinancing
- Order a Phase I. We review tenant history, permits, aerial photos, and agency files, and walk the whole building.
- Order a Phase II if needed. We target the sources the Phase I found. We send a written scope and price first.
- Plan cleanup or controls. Some sites need excavation. Others need a vapor mitigation system or a cleanup through Ecology’s Voluntary Cleanup Program.
Next step
Start with a Phase I Environmental Site Assessment. If you already know about solvents or a plating line, see our Phase II services. Call Kee Enviro at 206-914-4989.