You ordered a Phase I ESA. The report came back with a recognized environmental condition (REC). Now the deal feels uncertain. This guide explains what a REC means and the choices you have in Washington.
What a REC means
A REC is a finding in a Phase I ESA. It means the environmental professional found evidence that hazardous substances or petroleum have been released, or likely have been. [VERIFY exact ASTM E1527-21 definition wording]
A REC is not a lab result. It is a reasoned warning based on records, the site visit, and interviews. Common causes include:
- A former gas station or auto repair shop
- A former dry cleaner
- A current or former underground storage tank
- Stained soil, drums, or floor drains seen during the site visit
- A nearby site with known contamination that may affect yours
Why a REC matters in Washington
Washington’s Model Toxics Control Act (MTCA) makes cleanup liability strict, joint, and several. A new owner can be liable for contamination that a past owner caused. A buyer defense needs “all appropriate inquiry” before the purchase. The Phase I is part of that inquiry. But if you buy with a known REC and do nothing, you take on the risk with open eyes.
That is why lenders and attorneys pay close attention to RECs.
Your options after a REC
You have more than two choices. You do not have to pick between “close” and “walk away.”
| Option | When it fits | What to watch |
|---|---|---|
| Order a focused Phase II | You want facts before you decide | Time to close, drilling access, lab times |
| Ask the seller to test | The seller wants to keep the deal on track | Who picks the consultant and who can rely on the report |
| Negotiate price or a holdback | Risk is known and you accept some of it | Get a cost estimate before you agree to a number |
| Require a seller cleanup | Contamination is likely and the seller can act | Set clear goals, such as a No Further Action opinion |
| Close and plan your own cleanup | You plan to redevelop and can manage the work | Budget, schedule, and MTCA liability |
| Walk away | Risk is too high or too unclear | Check your contract’s due diligence deadline |
Your attorney should help you weigh these choices. Your lender may also set conditions.
Step by step: what to do this week
- Read the full Phase I, not just the summary. Note each REC and its source.
- Send the report to your lender and attorney.
- Check your due diligence deadline in the purchase agreement.
- Ask your consultant for a Phase II scope that targets each REC.
- Ask the seller for any past reports, tank records, or agency letters.
- Ask for more time in writing if you need it.
Scoping a focused Phase II
A good Phase II answers the questions the REC raised. It does not test everything. ASTM E1903 describes a process based on the scientific method. The aim is sound, valid data on actual conditions.
For a former fuel tank, that may mean soil samples near the tank pit. For a former dry cleaner, it may mean soil vapor and groundwater samples. ASTM E1903 also notes that one round of sampling may not be enough. Plan for that chance in your schedule.
Learn more in Phase I vs Phase II ESA.
Reading the Phase II results
The Phase II report compares lab results to MTCA cleanup levels in WAC 173-340. There are three common outcomes.
Results below cleanup levels
The REC may not be a real problem. Many deals move ahead at this point. Your lender may still want the report on file.
Results above cleanup levels in a small area
A small, defined area may be cleaned up before or after closing. Some owners use Ecology’s Voluntary Cleanup Program (VCP). A finished cleanup can get a No Further Action opinion. Ecology says these opinions “normally provide lenders and other government agencies the information they need.” Read about the VCP and No Further Action.
Results that show a larger problem
You may need more sampling to define the extent. This is where cost estimates matter. See our guide on contaminated soil removal cost in Washington.
Petroleum tank RECs
Releases from petroleum storage tank systems follow a different path in Washington. Ecology’s VCP page says those releases are not eligible for the VCP. Instead, the Pollution Liability Insurance Agency (PLIA) offers a Technical Assistance Program. PLIA is a separate agency, not part of Ecology.
Questions to ask your consultant
Before you approve a Phase II, ask these questions. The answers help you compare scopes and avoid surprises.
- Which REC does each sample location target?
- What will the lab test for, and why?
- How deep will the borings go?
- Will the work need groundwater or soil vapor samples?
- What happens if the first round of results is unclear?
- Who can rely on the report, and can the lender get a reliance letter?
- When will you have results, and when will the report be final?
A clear scope keeps cost and time in check. It also gives your lender and attorney a report they can use.
Keep your timeline realistic
| Step | Typical Kee Enviro time |
|---|---|
| Phase II scope and quote | [KEE TIMELINE] |
| Field work | [KEE TIMELINE] |
| Lab results | [KEE TIMELINE] |
| Phase II report | [KEE TIMELINE] |
These are placeholders. Ask for a written schedule with your quote.
Next step